Model NO. modular ups
Standby UPS Sine Wave Output UPS
Output Capacity Medium Type
Equipment Mode Decentralized
Brand Kstar
Voltage 380, 400, 415V
Efficiency >96% in Double Conversion > 99% in Energy Saver Sy
Frequency 50 or 60Hz
Output Power Factor 1
Power Rating 25-1560 Kw
Transport Package Carton
Specification 200KVA
Trademark kstar
Origin China
HS Code 8504402000
Product Description

25-1560kVA

HPM series UPS is developed as a high frequency on line modular UPS for medium and large data center, adopting fully digital control technology, fully guarantee power supply to operate reliably and stably; diversified option of modular power, accurately position user side requirements; flexible redundancy design greatly increase the system availabity, user can realize expansion as demand, and modular structure greatly increase the convenience for maintenance.
General Features

Adopting digital control design, and the control system is more reliable

High power density design, capacity of single power module is 6KVA/ 10KVA/ 15KVA/ 20KVA/ 25KVA/ 30KVA/ 40KVA, the height of all these modules is 3U.The power of system ranged from 6KVA to 520KVA corresponds to the number of parallel power modules from 1 to 13

Redundant control system, each power module is equipped independent control system, and control itself independently according to the sharing message, and the fault module separates from the system automatically

Support parallel expansion for cabinet, and parallel expansion is up to 4 cabinets.

Voltage of batteries can be configured flexibly, 1 input 1 output/ 3 input 1 output ±96Vdc/ ±108Vdc/ ±120Vdc(16/18/20PCS)selectable; 3 input 3 output±216Vdc/±228Vdc/±240Vdc (32/34/ 36/38/40PCS) selectable

Intelligent charging mode, Charging current can be configured , there are 3 charging mode which are constant current mode,constant voltage mode,floating charging mode, and the charging mode can be transfer smoothly.
Technical Specification

MODELHPM3325-250KVAHPM3330-90KVAHPM3330-150KVAHPM3330-300KVAHPM3340-200KVAHPM3340-320KVAHPM3340-400KVAHPM3340-520KVAHPM3340-800KVAHPM3340-1280KVA HPM3340-1560KVA
Capacity (VA/Watts)UPS cabinet 250k / 225k90k / 81k 150k / 135k300k / 270k200k/180k320k/288k400k / 360k520k / 468k800k / 720k1280k / 1152k1560k / 1404k
HPM module 25k / 22.5k 25k / 22.5k, 30k / 27k40k / 36k
INPUT
Nominal voltage380/400/415Vac, (3Ph+N+PE)
Operating voltage range208~478Vac for half load; 305~478Va c for full load
Operating frequency range40~70Hz
Power factor≥0.99
Harmonic distortion (THDi)3%(100% non-linear load)
Bypass voltage range380Vac Max.voltage: +25%(optional +10%,+15%,+20% )
400Vac Max.voltage: +20% (optional +10%,+15%)
415Vac Max.voltage: +15% (optional +10%)
Min.voltage: -45% (optional -20%,-30%)
Bypass frequency range Frequency synchronize tracing range:±10%
Generator accessSupport
OUTPUT
Rated voltage380/400/415Vac(3Ph+N+PE)
Power factor0.9
Voltage regulation±1%
FrequencyLine mode±1%/±2%/±4%/±5%/±10% of the rated frequency(optional)
Bat. mode(50/60±0.1%)Hz
Crest factor3:1
Harmonic distortion (THDv)≤2% with linear load
≤5% with non-linear load
Efficiency95.00%
BATTERY
Battery voltage±192/±204/±216/±228/±240Vdc; Battery quantity(optional)
Charging current(A)UPS cabinet 60A (Max.)30A (Max.)50A (Max.)100A (Max.)50A (Max.)80A (Max.)100A (Max.)130A (Max.)200A (Max.)320A (Max.)390A (Max.)
HPM module 6A (Max.) 25kVA:6A (Max.) / 30kVA:10A (Max.)10A (Max.)
Backup time Depends on the capacity of external batteries
SYSTEM FEATURES
Transfer timeUtility to battery:0ms; Utility to bypass:0ms
OverloadLine modeLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% turn to bypass mode immediately
Bat. modeLoad≤110%: last 10min,≤125%: last 1min,≤150%: last 1S,≥150% shut down UPS immediatelyLoad≤110%: last 60min,≤125%: last 10min,≤150%: last 1min,≥150% shut down UPS immediately
Bypass mode Breaker (25kVA:40A) Breaker ( 25kVA:40A / 30kVA:60A) 40kVA:95A
Short circuitHold whole system
Noise suppressionComplies with EN62040-2
Communication interfaceUPS cabinet : RS232, RS485, Dry contact, Intelligent slot x 2(SNMP card,Relay card optional);
HPM series UPS module: RS232
ENVIRONMENT
Operating temperature0~40ºC
Storage temperature-25~55ºC
Humidity range0~95% (Non-condensing)
Altitude<1500m. When >1500m, derating power for use
Noise level<70dB<65dB<70dB<73dB
PHYSICAL
Dimension D×W×H (mm)UPS cabinet 1100×600×2000 840×600×14001100×600×2000 850×600×1600850×600×2000 850×1200×2000850×2000×2000850×3400×20004800×850×2000
HPM module 443x580x131 (3U)
Net weight (kg)UPS cabinet 29015817030725132054098014002800
HPM module32 25kVA/32; 30kVA/33.536
STANDARDS
Safety IEC/EN62040-1,IEC/EN60950-1
EMCIEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8